Reverse Osmosis — Brine Concentration & ZLD

SP-XR Series — High-Ratio Concentration Membranes

XR60, XR100 and XR120 for brine concentration up to 130,000 ppm

Product description

XR60 is engineered for high-demand scenarios including zero liquid discharge (ZLD) and brine concentration. It delivers exceptional permeate flux even when processing high-concentration brines, directly reducing operational energy consumption, and offers inherent anti-fouling capability for stability in challenging feedwater.

XR100 addresses intensive ZLD and brine concentration needs, delivering exceptional permeate flux at high concentration while integrating anti-fouling capability that enhances stability and longevity in complex, fouling-prone feedwaters.

XR120 is purpose-built for extreme concentration scenarios, focusing on flux enhancement without compromising high salinity tolerance, and maintaining robust performance when processing highly concentrated brines.

Specifications

Product specifications
Membrane ModelEffective Area ft² (m²)Feed ChannelMax. Feed Pressure psi (MPa)Feed TDS mg/LConcentrate TDS mg/L
SP-XR60-400400 (37)Standard942 (6.5)32,000> 60,000
SP-XR60-350350 (33)HDG942 (6.5)32,000> 60,000
SP-XR100-400400 (37)Standard1087.5 (7.5)60,000100,000
SP-XR100-350350 (33)HDG1087.5 (7.5)60,000100,000
SP-XR120-400400 (37)Standard1087.5 (7.5)60,000130,000
SP-XR120-350350 (33)HDG1087.5 (7.5)60,000130,000

Data based on test results with six 8-inch elements in a vessel, 25°C (77°F), NaCl solution, pH 8.

SP-XR Series — High-Ratio Concentration Membranes — product view

Performance figures are nominal values obtained under the standard test conditions stated with each table. Actual performance varies with feedwater chemistry, pretreatment, flux, recovery, temperature, pressure and operating practice. Individual element flow may vary from the nominal value. Specifications are subject to change without notice — request the current datasheet before specifying.

Operating & cleaning limits

  • Maximum Operating Pressure 83 bar (1200 psi)
  • Maximum Operating Temperature 45°C (113°F)
  • Maximum Element Pressure Drop 1.0 bar (15 psi)
  • pH Range Continuous Operation 2–11
  • pH Range Short-Term Cleaning 1–13
  • Maximum Feed SDI (SDI₁₅) 5.0
  • Free Chlorine Tolerance < 0.1 ppm

Notes

  • Permeate flow for individual elements may vary ±15% from the value specified.
  • Active membrane area guaranteed ±4%.
  • Stabilized salt rejection is generally achieved within 24–48 hours of continuous use, depending upon feedwater characteristics and operating conditions.

Need a datasheet or pilot support?

Share your feedwater analysis and target recovery — our engineers will recommend the right element and array configuration.